TMI Watch IEEE Transactions on Medical Imaging metadata monitor

Volume 19, Issue 6

9 articles collected from IEEE Xplore web pages.

Latest update 2026/06/07 08:59
New 0 Existing 0
Previous Page 1 of 1 Next
Earlier collected articles较早收录文章

Regularization for uniform spatial resolution properties in penalized-likelihood image reconstruction

惩罚似然图像重建中均匀空间分辨率特性的正则化方法

J.W. Stayman, J.A. Fessler

Body Part 身体部位
Lung
Modality 模态
PET
Abstract / 摘要
English

Traditional space-invariant regularization methods in tomographic image reconstruction using penalized-likelihood estimators produce images with nonuniform spatial resolution properties. The local point spread functions that quantify the smoothing properties of such estimators are space variant, asymmetric, and object-dependent even for space invariant imaging systems. The authors propose a new quadratic regularization scheme for tomographic imaging systems that yields increased spatial uniformity and is motivated by the least-squares fitting of a parameterized local impulse response to a desired global response. The authors have developed computationally efficient methods for PET systems with shift-invariant geometric responses. They demonstrate the increased spatial uniformity of this new method versus conventional quadratic regularization schemes in simulated PET thorax scans.

中文

在采用惩罚似然估计器的层析图像重建中,传统的空间不变正则化方法会产生空间分辨率不均匀的图像。即使是空间不变的成像系统,量化此类估计器平滑特性的局部点扩散函数也是空间可变、非对称且依赖于物体的。作者针对层析成像系统提出了一种新的二次正则化方案,该方案通过将参数化局部脉冲响应的最小二乘拟合到期望的全局响应,从而提高空间均匀性。作者为具有移不变几何响应的PET系统开发了计算高效的方法。他们在模拟PET胸部扫描中展示了这种新方法相比传统二次正则化方案在空间均匀性上的提升。

Author Info / 作者信息
J.W. Stayman EECS Department, University of Michigan, Ann Arbor, MI, USA 密歇根大学安娜堡分校电气工程与计算机科学系
J.A. Fessler EECS Department, University of Michigan, Ann Arbor, MI, USA 密歇根大学安娜堡分校电气工程与计算机科学系

Gray-scale skeletonization of small vessels in magnetic resonance angiography

磁共振血管造影中小血管的灰度骨架化

P.J. Yim, P.L. Choyke, R.M. Summers

Body Part 身体部位
Vessel
Modality 模态
MRIAngiography
Abstract / 摘要
English

Interpretation of magnetic resonance angiography (MRA) is problematic due to complexities of vascular shape and to artifacts such as the partial volume effect. The authors present new methods to assist in the interpretation of MRA. These include methods for detection of vessel paths and for determination of branching patterns of vascular trees. They are based on the ordered region growing (ORG) al...

中文

由于血管形状的复杂性和部分容积效应等伪影,磁共振血管造影(MRA)的解释存在问题。作者提出了新的方法以辅助MRA的解释,包括血管路径检测和血管树分支模式确定的方法。这些方法基于有序区域生长(ORG)算法……

Author Info / 作者信息
P.J. Yim Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
P.L. Choyke Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
R.M. Summers Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

A modular software system for computer-aided surgery and its first application in oral implantology

计算机辅助手术的模块化软件系统及其在口腔种植学中的首次应用

W. Birkfellner, K. Huber, A. Larson, D. Hanson, M. Diemling, P. Homolka, H. Bergmann

Body Part 身体部位
Head and Neck
Modality 模态
CT
Abstract / 摘要
English

Development of complex software applications in image guided therapy (IGT) is often complicated by the fact that providing basic functionality for image processing and user interaction from a graphical user interfaces (GUI) requires considerable manpower for software development. The authors present a programming environment that combines the high-level image processing library AVW, in-house devel...

中文

在图像引导治疗(IGT)中开发复杂的软件应用程序常常因一个事实而变得复杂:从图形用户界面(GUI)提供图像处理和用户交互的基本功能需要大量的人力进行软件开发。作者介绍了一种编程环境,它结合了高级图像处理库AVW、内部开发的...

Author Info / 作者信息
W. Birkfellner Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
K. Huber Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
A. Larson Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
D. Hanson Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
M. Diemling Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
P. Homolka Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
H. Bergmann Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Ultrasound measurement of brachial flow-mediated vasodilator response

超声测量肱动脉血流介导的血管舒张反应

Liexiang Fan, P. Santago, Huai Jiang, D.M. Herrington

Body Part 身体部位
Vessel
Modality 模态
US
Abstract / 摘要
English

Brachial artery flow-mediated vasodilation is increasingly used as a measure of endothelial function. High resolution ultrasound provides a noninvasive method to observe this flow-mediated vasodilation by monitoring the diameter of the artery over time following a transient flow stimulus. Since hundreds of ultrasound images are required to continuously monitor brachial diameter for the 2-3 min dur...

中文

肱动脉血流介导的血管舒张功能越来越多地被用作内皮功能的衡量指标。高分辨率超声通过监测短暂血流刺激后动脉直径随时间的变化,提供了一种非侵入性方法来观察这种血流介导的血管舒张。由于需要数百张超声图像来持续监测肱动脉直径达2-3分钟...

Author Info / 作者信息
Liexiang Fan Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
P. Santago Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Huai Jiang Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
D.M. Herrington Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Analysis of geometrical distortion and statistical variance in length, area, and volume in a linearly scanned 3-D ultrasound image

线性扫描三维超声图像中长度、面积和体积的几何畸变及统计方差分析

H.N. Cardinal, J.D. Gill, A. Fenster

Body Part 身体部位
Abdomen
Modality 模态
US
Abstract / 摘要
English

A linearly scanned three-dimensional (3-D) ultrasound imaging system is considered. The transducer array is initially oriented along the x axis and aimed in the y direction. After being tilted by an angle /spl theta/ about the x axis, and then swiveled by an angle /spl phi/ about the y axis, it is translated in the z direction, in steps of size d, to acquire a series of parallel two-dimensional (2...

中文

考虑一种线性扫描三维超声成像系统。换能器阵列最初沿x轴方向,指向y方向。在绕x轴倾斜角度/spl theta/,然后绕y轴旋转角度/spl phi/后,它以步长d沿z方向平移,以获取一系列平行的二维图像...

Author Info / 作者信息
H.N. Cardinal Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
J.D. Gill Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
A. Fenster Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Deformable boundary detection of stents in angiographic images

血管造影图像中支架的可变形边界检测

I. Kompatsiaris, D. Tzovaras, V. Koutkias, M.G. Strintzis

Body Part 身体部位
HeartVessel
Modality 模态
Angiography
Abstract / 摘要
English

A procedure is described for deformable boundary detection of medical tools, called stents, in angiographic images. A stent is a surgical stainless steel coil that is placed in the artery in order to improve blood circulation in regions where a stenosis has appeared. Assuming initially a set of three-dimensional (3-D) models of stents and using perspective projection of various deformations of the...

中文

描述了一种用于血管造影图像中医疗工具(称为支架)的可变形边界检测程序。支架是一种外科不锈钢线圈,放置在动脉中,以改善出现狭窄区域的血流循环。假设初始有一组三维(3-D)支架模型,并使用各种变形的透视投影...

Author Info / 作者信息
I. Kompatsiaris Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
D. Tzovaras Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
V. Koutkias Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
M.G. Strintzis Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

A filter design method for minimizing ringing in a region of interest in MR spectroscopic images

一种用于最小化磁共振波谱成像中感兴趣区域振铃的滤波器设计方法

T. Bakir, S.J. Reeves

Body Part 身体部位
Brain
Modality 模态
MRI
Abstract / 摘要
English

Magnetic resonance spectroscopic imaging (MRSI) requires a relatively long time to sample k-space (the spatial frequency domain), effectively lowpass filtering the resulting reconstructed image. Ringing is especially problematic when a region of interest (ROI) is close to a bright region outside the ROI, since the bright region tends to create a ringing artifact into the ROI due to the lowpass nat...

中文

磁共振波谱成像(MRSI)需要相对较长的时间来采样k空间(空间频率域),从而对重建图像进行低通滤波。当感兴趣区域(ROI)靠近ROI外的明亮区域时,振铃问题尤其严重,因为明亮区域由于低通特性容易在ROI中产生振铃伪影...

Author Info / 作者信息
T. Bakir Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
S.J. Reeves Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Using an MRI distortion transfer function to characterize the ghosts in motion-corrupted images

利用MRI畸变传递函数表征运动伪影图像中的鬼影

Weifang Yang, M.R. Smith

Body Part 身体部位
None
Modality 模态
MRI
Abstract / 摘要
English

Motion artefact suppression remains an active topic in MRI. In this paper, the authors suggest that certain nonrigid, or spatially variant, characteristics of motion of an object can be represented by extending the work of Mitsa et al. (1989). This empirical extension uses a ghost distortion transfer function (GTDF) applied to the k-space (frequency domain) data. The authors demonstrate the variet...

中文

运动伪影抑制仍然是MRI中的一个活跃话题。本文中,作者提出,通过扩展Mitsa等人(1989)的工作,可以表示物体运动的某些非刚性或空间变化的特性。这种经验扩展使用了一个应用于k空间(频域)数据的鬼影畸变传递函数(GTDF)。作者展示了多种...

Author Info / 作者信息
Weifang Yang Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
M.R. Smith Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

NCI initiative: development of novel imaging technologies

NCI倡议: 新型成像技术的发展

L.P. Clarke

Body Part 身体部位
None
Modality 模态
None
Author Info / 作者信息
L.P. Clarke Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Previous Page 1 of 1 Next