TMI Watch IEEE Transactions on Medical Imaging metadata monitor

Volume 5, Issue 1

3 articles collected from IEEE Xplore web pages.

Latest update 2026/06/07 08:59
New 0 Existing 0
Previous Page 1 of 1 Next
Earlier collected articles较早收录文章

C. B. Ahn, J. H. Kim, Z. H. Cho

Body Part 身体部位
Pending
Modality 模态
Pending
Abstract / 摘要
English

An improved echo planar high-speed imaging technique using spiral scan is presented and experimental advantages are discussed. This proposed spiral-scan echo planar imaging (SEPI) technique employs two linearly increasing sinusoidal gradient fields, which results in a spiral trajectory in the spatial frequency domain (k-domain) that covers the entire frequency domain uniformly. The advantages of the method are: 1) circularly symmetric T2 weighting, resulting in a circularly symmetric point spread function in the image domain; 2) elimination of discontinuities in gradient waveforms which in turn will reduce initial transient as well as steady-state distortions; and 3) effective rapid spiral-scan from dc to high frequency in a continuous fashion, which ensures multiple pulsing with interlacing for further resolution improvement without T2 decay image degradation. Some preliminary experimental results will be presented and further possible improvements suggested.

中文

中文摘要翻译待生成

Author Info / 作者信息
C. B. Ahn Department of Electrical Science, Korea Advanced Institute of Science and Technology, Seoul, South Korea 机构中文翻译待生成或 IEEE 未提供机构
J. H. Kim Department of Electrical Science, Korea Advanced Institute of Science and Technology, Seoul, South Korea 机构中文翻译待生成或 IEEE 未提供机构
Z. H. Cho Department of Radiological Sciences, University of California, Irvine, CA, USA; Department of Electrical Science, Korea Advanced Institute of Science and Technology, Seoul, South Korea 机构中文翻译待生成或 IEEE 未提供机构

Grant T. Gullberg, Carl R. Crawford, Benjamin M. W. Tsui

Body Part 身体部位
Pending
Modality 模态
Pending
Abstract / 摘要
English

A convolutional backprojection algorithm is derived for a fan beam geometry that has its center-of-rotation displaced from the midline of the fan beam. In single photon emission computed tomography (SPECT), where a transaxial converging collimator is used with a rotating gamma camera, it is difficult to precisely align the collimator so that the mechanical center-of-rotation is colinear with the m...

中文

中文摘要翻译待生成

Author Info / 作者信息
Grant T. Gullberg Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Carl R. Crawford Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Benjamin M. W. Tsui Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Karl Heinz Hohne, Ralph Bernstein

Body Part 身体部位
Pending
Modality 模态
Pending
Abstract / 摘要
English

For the 3D-reconstruction of organ surfaces from tomograms, a shading method based on the partial volume effect is presented. In contrast to methods based on the depth and/or the angle of the voxel surface, here the gray-level gradient along the surface is used for shading. It is shown, that at least for bone and soft tissue surfaces, the results are superior to conventional shading. This is due t...

中文

中文摘要翻译待生成

Author Info / 作者信息
Karl Heinz Hohne Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Ralph Bernstein Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Previous Page 1 of 1 Next