Volume 5, Issue 1
3 articles collected from IEEE Xplore web pages.
Earlier collected articles较早收录文章
March 1986 · Volume 5, Issue 1 · Vol. 5 · Issue 1 · DOI 10.1109/TMI.1986.4307732
C. B. Ahn, J. H. Kim, Z. H. Cho
Abstract / 摘要
EnglishAn improved echo planar high-speed imaging technique using spiral scan is presented and experimental advantages are discussed. This proposed spiral-scan echo planar imaging (SEPI) technique employs two linearly increasing sinusoidal gradient fields, which results in a spiral trajectory in the spatial frequency domain (k-domain) that covers the entire frequency domain uniformly. The advantages of the method are: 1) circularly symmetric T2 weighting, resulting in a circularly symmetric point spread function in the image domain; 2) elimination of discontinuities in gradient waveforms which in turn will reduce initial transient as well as steady-state distortions; and 3) effective rapid spiral-scan from dc to high frequency in a continuous fashion, which ensures multiple pulsing with interlacing for further resolution improvement without T2 decay image degradation. Some preliminary experimental results will be presented and further possible improvements suggested.
Author Info / 作者信息
C. B. Ahn
Department of Electrical Science, Korea Advanced Institute of Science and Technology, Seoul, South Korea
机构中文翻译待生成或 IEEE 未提供机构
J. H. Kim
Department of Electrical Science, Korea Advanced Institute of Science and Technology, Seoul, South Korea
机构中文翻译待生成或 IEEE 未提供机构
Z. H. Cho
Department of Radiological Sciences, University of California, Irvine, CA, USA; Department of Electrical Science, Korea Advanced Institute of Science and Technology, Seoul, South Korea
机构中文翻译待生成或 IEEE 未提供机构
Translation: pending
AI: pending
Article 4307732
March 1986 · Volume 5, Issue 1 · Vol. 5 · Issue 1 · DOI 10.1109/TMI.1986.4307735
Grant T. Gullberg, Carl R. Crawford, Benjamin M. W. Tsui
Abstract / 摘要
EnglishA convolutional backprojection algorithm is derived for a fan beam geometry that has its center-of-rotation displaced from the midline of the fan beam. In single photon emission computed tomography (SPECT), where a transaxial converging collimator is used with a rotating gamma camera, it is difficult to precisely align the collimator so that the mechanical center-of-rotation is colinear with the m...
Author Info / 作者信息
Grant T. Gullberg
Affiliation not provided by IEEE Xplore
机构中文翻译待生成或 IEEE 未提供机构
Carl R. Crawford
Affiliation not provided by IEEE Xplore
机构中文翻译待生成或 IEEE 未提供机构
Benjamin M. W. Tsui
Affiliation not provided by IEEE Xplore
机构中文翻译待生成或 IEEE 未提供机构
Translation: pending
AI: pending
Article 4307735
March 1986 · Volume 5, Issue 1 · Vol. 5 · Issue 1 · DOI 10.1109/TMI.1986.4307738
Karl Heinz Hohne, Ralph Bernstein
Abstract / 摘要
EnglishFor the 3D-reconstruction of organ surfaces from tomograms, a shading method based on the partial volume effect is presented. In contrast to methods based on the depth and/or the angle of the voxel surface, here the gray-level gradient along the surface is used for shading. It is shown, that at least for bone and soft tissue surfaces, the results are superior to conventional shading. This is due t...
Author Info / 作者信息
Karl Heinz Hohne
Affiliation not provided by IEEE Xplore
机构中文翻译待生成或 IEEE 未提供机构
Ralph Bernstein
Affiliation not provided by IEEE Xplore
机构中文翻译待生成或 IEEE 未提供机构
Translation: pending
AI: pending
Article 4307738