TMI Watch IEEE Transactions on Medical Imaging metadata monitor

Volume 34, Issue 2

36 articles collected from IEEE Xplore web pages.

Latest update 2026/06/07 08:59
New 0 Existing 0
Previous Page 1 of 2 Next
Earlier collected articles较早收录文章

In Vivo Acoustic Super-Resolution and Super-Resolved Velocity Mapping Using Microbubbles

利用微泡的体内声学超分辨与超分辨速度成像

Kirsten Christensen-Jeffries, Richard J. Browning, Meng-Xing Tang, Christopher Dunsby, Robert J. Eckersley

Body Part 身体部位
VesselHead and Neck
Modality 模态
US
Abstract / 摘要
English

The structure of microvasculature cannot be resolved using standard clinical ultrasound (US) imaging frequencies due to the fundamental diffraction limit of US waves. In this work, we use a standard clinical US system to perform in vivo sub-diffraction imaging on a CD1, female mouse aged eight weeks by localizing isolated US signals from microbubbles flowing within the ear microvasculature, and compare our results to optical microscopy. Furthermore, we develop a new technique to map blood velocity at super-resolution by tracking individual bubbles through the vasculature. Resolution is improved from a measured lateral and axial resolution of 112 μm and 94 μm respectively in original US data, to super-resolved images of microvasculature where vessel features as fine as 19 μm are clearly visualized. Velocity maps clearly distinguish opposing flow direction and separated speed distributions in adjacent vessels, thereby enabling further differentiation between vessels otherwise not spatially separated in the image. This technique overcomes the diffraction limit to provide a noninvasive means of imaging the microvasculature at super-resolution, to depths of many centimeters. In the future, this method could noninvasively image pathological or therapeutic changes in the microvasculature at centimeter depths in vivo.

中文

由于超声波的固有衍射极限,标准临床超声成像频率无法解析微血管结构。在本工作中,我们使用标准临床超声系统,通过定位来自流经耳微血管的微泡的孤立超声信号,对一只八周龄的CD1雌性小鼠进行体内亚衍射成像,并将我们的结果与光学显微镜进行比较。此外,我们开发了一种新技术,通过追踪血管中的单个气泡来绘制超分辨血流速度。分辨率从原始超声数据中测量的横向112 μm和轴向94 μm提高到微血管超分辨图像,其中可清晰观察到细至19 μm的血管特征。速度图清晰区分相邻血管中的相反流动方向和分离的速度分布,从而进一步区分图像中原本未空间分离的血管。该技术突破了衍射极限,提供了一种非侵入性的超分辨微血管成像方法,深度可达数厘米。未来,该方法可无创地成像体内厘米深度处微血管的病理或治疗变化。

Author Info / 作者信息
Kirsten Christensen-Jeffries Biomedical Engineering Department, Kings College London, London, UK 英国伦敦国王学院生物医学工程系
Richard J. Browning Biomedical Engineering Department, Kings College London, London, UK; Institute of Biomedical Engineering, University of Oxford, Oxford, UK 英国伦敦国王学院生物医学工程系;英国牛津大学生物医学工程研究所
Meng-Xing Tang Department of Bioengineering, Imperial College London, London, UK 英国伦敦帝国理工学院生物工程系
Christopher Dunsby Centre for Histopathology, Imperial College London, London, UK 英国伦敦帝国理工学院组织病理学中心
Robert J. Eckersley Biomedical Engineering Department, Kings College London, London, UK 英国伦敦国王学院生物医学工程系

Towards Large-Scale Histopathological Image Analysis: Hashing-Based Image Retrieval

迈向大规模组织病理图像分析:基于哈希的图像检索

Xiaofan Zhang, Wei Liu, Murat Dundar, Sunil Badve, Shaoting Zhang

Body Part 身体部位
None
Modality 模态
Histopathology
Abstract / 摘要
English

Automatic analysis of histopathological images has been widely utilized leveraging computational image-processing methods and modern machine learning techniques. Both computer-aided diagnosis (CAD) and content-based image-retrieval (CBIR) systems have been successfully developed for diagnosis, disease detection, and decision support in this area. Recently, with the ever-increasing amount of annota...

中文

利用计算图像处理方法和现代机器学习技术,自动分析组织病理图像已被广泛应用。在该领域,计算机辅助诊断(CAD)和基于内容的图像检索(CBIR)系统已成功开发用于诊断、疾病检测和决策支持。近年来,随着注释数量的不断增加...

Author Info / 作者信息
Xiaofan Zhang Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Wei Liu Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Murat Dundar Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Sunil Badve Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Shaoting Zhang Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Automated 3-D Retinal Layer Segmentation of Macular Optical Coherence Tomography Images With Serous Pigment Epithelial Detachments

伴有浆液性色素上皮脱离的黄斑区光学相干断层扫描图像的自动三维视网膜层分割

Fei Shi, Xinjian Chen, Heming Zhao, Weifang Zhu, Dehui Xiang, Enting Gao, Milan Sonka, Haoyu Chen

Body Part 身体部位
Eye
Modality 模态
OCT
Abstract / 摘要
English

Automated retinal layer segmentation of optical coherence tomography (OCT) images has been successful for normal eyes but becomes challenging for eyes with retinal diseases if the retinal morphology experiences critical changes. We propose a method to automatically segment the retinal layers in 3-D OCT data with serous retinal pigment epithelial detachments (PED), which is a prominent feature of m...

中文

光学相干断层扫描(OCT)图像的自动视网膜层分割在正常眼中已取得成功,但如果视网膜形态发生关键变化,对于患有视网膜疾病的眼则变得具有挑战性。我们提出一种方法,用于自动分割伴有浆液性视网膜色素上皮脱离(PED)的3D OCT数据中的视网膜层,这是...的一个显著特征。

Author Info / 作者信息
Fei Shi Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Xinjian Chen Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Heming Zhao Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Weifang Zhu Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Dehui Xiang Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Enting Gao Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Milan Sonka Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Haoyu Chen Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Simultaneous Phase Unwrapping and Removal of Chemical Shift (SPURS) Using Graph Cuts: Application in Quantitative Susceptibility Mapping

同时相位解包裹与化学位移去除(SPURS)使用图割:在定量磁化率成像中的应用

Jianwu Dong, Tian Liu, Feng Chen, Dong Zhou, Alexey Dimov, Ashish Raj, Qiang Cheng, Pascal Spincemaille

Body Part 身体部位
Brain
Modality 模态
MRI
Abstract / 摘要
English

Quantitative susceptibility mapping (QSM) is a magnetic resonance imaging technique that reveals tissue magnetic susceptibility. It relies on having a high quality field map, typically acquired with a relatively long echo spacing and long final TE. Applications of QSM outside the brain require the removal of fat contributions to the total signal phase. However, current water/fat separation methods...

中文

定量磁化率成像(QSM)是一种揭示组织磁化率的磁共振成像技术。它依赖于高质量场图,通常通过相对较长的回波间隔和较长的最终TE获取。QSM在脑部以外的应用需要去除脂肪对总信号相位的贡献。然而,当前的水/脂肪分离方法...

Author Info / 作者信息
Jianwu Dong Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Tian Liu Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Feng Chen Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Dong Zhou Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Alexey Dimov Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Ashish Raj Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Qiang Cheng Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Pascal Spincemaille Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Microwave Medical Imaging Based on Sparsity and an Iterative Method With Adaptive Thresholding

基于稀疏性和自适应阈值迭代方法的微波医学成像

Masoumeh Azghani, Panagiotis Kosmas, Farokh Marvasti

Body Part 身体部位
Breast
Modality 模态
US
Abstract / 摘要
English

We propose a new image recovery method to improve the resolution in microwave imaging applications. Scattered field data obtained from a simplified breast model with closely located targets is used to formulate an electromagnetic inverse scattering problem, which is then solved using the Distorted Born Iterative Method (DBIM). At each iteration of the DBIM method, an underdetermined set of linear ...

中文

我们提出了一种新的图像恢复方法,以提高微波成像应用中的分辨率。使用从具有近距离目标的简化乳房模型获得的散射场数据来制定电磁逆散射问题,然后使用扭曲玻恩迭代法(DBIM)求解。在DBIM方法的每次迭代中,一组欠定线性...

Author Info / 作者信息
Masoumeh Azghani Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Panagiotis Kosmas Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Farokh Marvasti Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Ultrasound RF Time Series for Classification of Breast Lesions

用于乳腺病变分类的超声射频时间序列

Nishant Uniyal, Hani Eskandari, Purang Abolmaesumi, Samira Sojoudi, Paula Gordon, Linda Warren, Robert N. Rohling, Septimiu E. Salcudean

Body Part 身体部位
Breast
Modality 模态
US
Abstract / 摘要
English

This work reports the use of ultrasound radio frequency (RF) time series analysis as a method for ultrasound-based classification of malignant breast lesions. The RF time series method is versatile and requires only a few seconds of raw ultrasound data with no need for additional instrumentation. Using the RF time series features, and a machine learning framework, we have generated malignancy maps...

中文

本工作报告了使用超声射频(RF)时间序列分析作为基于超声的恶性乳腺病变分类方法。RF时间序列方法用途广泛,仅需几秒钟的原始超声数据,无需额外仪器。利用RF时间序列特征和机器学习框架,我们生成了恶性图谱...

Author Info / 作者信息
Nishant Uniyal Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Hani Eskandari Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Purang Abolmaesumi Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Samira Sojoudi Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Paula Gordon Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Linda Warren Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Robert N. Rohling Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Septimiu E. Salcudean Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Implications of Ultrasound Frequency in Optoacoustic Mesoscopy of the Skin

超声频率在皮肤光声介观成像中的意义

Mathias Schwarz, Murad Omar, Andreas Buehler, Juan Aguirre, Vasilis Ntziachristos

Body Part 身体部位
Skin
Modality 模态
US
Abstract / 摘要
English

Raster-scan optoacoustic mesoscopy (RSOM) comes with high potential for in vivo diagnostic imaging in dermatology, since it allows for high resolution imaging of the natural chromophores melanin, and hemoglobin at depths of several millimeters. We have applied ultra-wideband RSOM, in the 10-160 MHz frequency band, to image healthy human skin at distinct locations. We analyzed the anatomical inform...

中文

光栅扫描光声介观成像(RSOM)在皮肤科体内诊断成像方面具有很高的潜力,因为它能够在几毫米深度的高分辨率下对天然发色团黑色素和血红蛋白进行成像。我们应用了10-160 MHz频段的超宽带RSOM,对不同部位的健康人体皮肤进行了成像。我们分析了解剖学信息...

Author Info / 作者信息
Mathias Schwarz Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Murad Omar Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Andreas Buehler Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Juan Aguirre Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Vasilis Ntziachristos Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Automatic Deformable MR-Ultrasound Registration for Image-Guided Neurosurgery

用于图像引导神经外科的自动可变形MR-超声配准

Hassan Rivaz, Sean Jy-Shyang Chen, D. Louis Collins

Body Part 身体部位
Brain
Modality 模态
MRIUS
Abstract / 摘要
English

In this work, we present a novel algorithm for registration of 3-D volumetric ultrasound (US) and MR using Robust PaTch-based cOrrelation Ratio (RaPTOR). RaPTOR computes local correlation ratio (CR) values on small patches and adds the CR values to form a global cost function. It is therefore invariant to large amounts of spatial intensity inhomogeneity. We also propose a novel outlier suppression...

中文

在本文中,我们提出了一种新颖的算法,用于使用基于鲁棒补丁的相关比(RaPTOR)对三维容积超声(US)和MR进行配准。RaPTOR计算小补丁上的局部相关比(CR)值,并将CR值相加形成全局成本函数。因此,它对大量的空间强度不均匀性具有不变性。我们还提出了一种新颖的异常值抑制方法...

Author Info / 作者信息
Hassan Rivaz Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Sean Jy-Shyang Chen Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
D. Louis Collins Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Electronic Field Free Line Rotation and Relaxation Deconvolution in Magnetic Particle Imaging

磁粒子成像中的电子场自由线旋转与弛豫反卷积

Klaas Bente, Matthias Weber, Matthias Graeser, Timo F. Sattel, Marlitt Erbe, Thorsten M. Buzug

Body Part 身体部位
None
Modality 模态
None
Abstract / 摘要
English

It has been shown that magnetic particle imaging (MPI), an imaging method suggested in 2005, is capable of measuring the spatial distribution of magnetic nanoparticles. Since the particles can be administered as biocompatible suspensions, this method promises to perform well as a tracer-based medical imaging technique. It is capable of generating real-time images, which will be useful in intervent...

中文

已有研究表明,2005年提出的磁粒子成像(MPI)方法能够测量磁性纳米颗粒的空间分布。由于这些颗粒可以以生物相容性悬浮液的形式给药,该方法有望作为一种基于示踪剂的医学成像技术表现出色。它能够生成实时图像,这将在介入治疗中发挥作用……

Author Info / 作者信息
Klaas Bente Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Matthias Weber Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Matthias Graeser Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Timo F. Sattel Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Marlitt Erbe Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Thorsten M. Buzug Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Tracking Multiple Particles in Fluorescence Time-Lapse Microscopy Images via Probabilistic Data Association

通过概率数据关联在荧光延时显微图像中追踪多个粒子

William J. Godinez, Karl Rohr

Body Part 身体部位
None
Modality 模态
Microscopy
Abstract / 摘要
English

Tracking subcellular structures as well as viral structures displayed as `particles' in fluorescence microscopy images yields quantitative information on the underlying dynamical processes. We have developed an approach for tracking multiple fluorescent particles based on probabilistic data association. The approach combines a localization scheme that uses a bottom-up strategy based on the spot-en...

中文

追踪荧光显微图像中显示为'粒子'的亚细胞结构以及病毒结构,可以获取关于潜在动态过程的定量信息。我们开发了一种基于概率数据关联的荧光粒子多目标追踪方法。该方法结合了一种定位方案,该方案采用基于点增强的自下而上策略...

Author Info / 作者信息
William J. Godinez Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Karl Rohr Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Fast X-Ray CT Image Reconstruction Using a Linearized Augmented Lagrangian Method With Ordered Subsets

使用线性化增广拉格朗日方法结合有序子集的快速X射线CT图像重建

Hung Nien, Jeffrey A. Fessler

Body Part 身体部位
None
Modality 模态
CT
Abstract / 摘要
English

Augmented Lagrangian (AL) methods for solving convex optimization problems with linear constraints are attractive for imaging applications with composite cost functions due to the empirical fast convergence rate under weak conditions. However, for problems such as X-ray computed tomography (CT) image reconstruction, where the inner least-squares problem is challenging and requires iterations, AL m...

中文

增广拉格朗日(AL)方法用于求解带有线性约束的凸优化问题,由于在弱条件下具有经验快速收敛速度,对于具有复合代价函数的成像应用具有吸引力。然而,对于诸如X射线计算机断层扫描(CT)图像重建等问题,内部最小二乘问题具有挑战性且需要迭代,AL方法...

Author Info / 作者信息
Hung Nien Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Jeffrey A. Fessler Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Regularization Designs for Uniform Spatial Resolution and Noise Properties in Statistical Image Reconstruction for 3-D X-ray CT

3-D X射线CT统计图像重建中均匀空间分辨率和噪声特性的正则化设计

Jang Hwan Cho, Jeffrey A. Fessler

Body Part 身体部位
None
Modality 模态
CT
Abstract / 摘要
English

Statistical image reconstruction methods for X-ray computed tomography (CT) provide improved spatial resolution and noise properties over conventional filtered back-projection (FBP) reconstruction, along with other potential advantages such as reduced patient dose and artifacts. Conventional regularized image reconstruction leads to spatially variant spatial resolution and noise characteristics be...

中文

X射线计算机断层扫描(CT)的统计图像重建方法在空间分辨率和噪声特性方面优于传统的滤波反投影(FBP)重建,同时还具有其他潜在优势,如降低患者剂量和伪影。传统的正则化图像重建会导致空间变异的空间分辨率和噪声特性...

Author Info / 作者信息
Jang Hwan Cho Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Jeffrey A. Fessler Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Patient-Specific Biomechanical Model for the Prediction of Lung Motion From 4-D CT Images

基于患者特定生物力学模型从4D CT图像预测肺运动

Bernhard Fuerst, Tommaso Mansi, Francois Carnis, Martin Sälzle, Jingdan Zhang, Jerome Declerck, Thomas Boettger, John Bayouth

Body Part 身体部位
Lung
Modality 模态
CT
Abstract / 摘要
English

This paper presents an approach to predict the deformation of the lungs and surrounding organs during respiration. The framework incorporates a computational model of the respiratory system, which comprises an anatomical model extracted from computed tomography (CT) images at end-expiration (EE), and a biomechanical model of the respiratory physiology, including the material behavior and interacti...

中文

本文提出了一种预测呼吸过程中肺及周围器官变形的方法。该框架包含一个呼吸系统的计算模型,该模型由从呼气末CT图像中提取的解剖模型和呼吸生理的生物力学模型(包括材料行为及相互作用)组成。

Author Info / 作者信息
Bernhard Fuerst Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Tommaso Mansi Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Francois Carnis Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Martin Sälzle Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Jingdan Zhang Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Jerome Declerck Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Thomas Boettger Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
John Bayouth Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Exact Confidence Intervals for Channelized Hotelling Observer Performance in Image Quality Studies

图像质量研究中通道化霍特林观察者性能的精确置信区间

Adam Wunderlich, Frédéric Noo, Brandon D. Gallas, Marta E. Heilbrun

Body Part 身体部位
None
Modality 模态
None
Abstract / 摘要
English

Task-based assessments of image quality constitute a rigorous, principled approach to the evaluation of imaging system performance. To conduct such assessments, it has been recognized that mathematical model observers are very useful, particularly for purposes of imaging system development and optimization. One type of model observer that has been widely applied in the medical imaging community is...

中文

基于任务的图像质量评估是对成像系统性能进行严格、有原则评估的一种方法。为了进行此类评估,人们认识到数学模型观察者非常有用,特别是在成像系统开发和优化方面。在医学影像界广泛使用的一种模型观察者是

Author Info / 作者信息
Adam Wunderlich Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Frédéric Noo Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Brandon D. Gallas Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Marta E. Heilbrun Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Tissue Electrical Property Mapping From Zero Echo-Time Magnetic Resonance Imaging

零回波时间磁共振成像的组织电特性映射

Seung-Kyun Lee, Selaka Bulumulla, Florian Wiesinger, Laura Sacolick, Wei Sun, Ileana Hancu

Body Part 身体部位
Brain
Modality 模态
MRI
Abstract / 摘要
English

The capability of magnetic resonance imaging (MRI) to produce spatially resolved estimation of tissue electrical properties (EPs) in vivo has been a subject of much recent interest. In this work we introduce a method to map tissue EPs from low-flip-angle, zero-echo-time (ZTE) imaging. It is based on a new theoretical formalism that allows calculation of EPs from the product of transmit and receive...

中文

磁共振成像(MRI)在体内产生组织电特性(EPs)的空间分辨估计的能力最近引起了广泛关注。在这项工作中,我们介绍了一种从低翻转角、零回波时间(ZTE)成像中映射组织EPs的方法。它基于一种新的理论形式,允许从发射和接收的乘积计算EPs...

Author Info / 作者信息
Seung-Kyun Lee Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Selaka Bulumulla Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Florian Wiesinger Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Laura Sacolick Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Wei Sun Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Ileana Hancu Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Benoit Diotte, Pascal Fallavollita, Lejing Wang, Simon Weidert, Ekkehard Euler, Peter Thaller, Nassir Navab

Body Part 身体部位
Bone
Modality 模态
X-Ray
Abstract / 摘要
English

The interlocking of intramedullary nails is a technically demanding procedure which involves a considerable amount of X-ray acquisitions; one study lists as many as 48 to successfully complete the procedure and fix screws into 4-6 mm distal holes of the nail. We propose to design an augmented radiolucent drill to assist surgeons in completing the distal locking procedure without any additional X-r...

中文

髓内钉的交锁是一项技术要求高的手术,需要进行大量的X射线采集;一项研究列出了多达48次X射线才能成功完成手术并将螺钉固定到钉子4-6毫米的远端孔中。我们提出设计一种增强型透光钻头,以帮助外科医生无需额外的X射线即可完成远端锁定手术。

Author Info / 作者信息
Benoit Diotte Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Pascal Fallavollita Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Lejing Wang Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Simon Weidert Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Ekkehard Euler Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Peter Thaller Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Nassir Navab Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Ultrasound Shear Wave Elasticity Imaging Quantifies Coronary Perfusion Pressure Effect on Cardiac Compliance

超声剪切波弹性成像量化冠状动脉灌注压对心脏顺应性的影响

Maryam Vejdani-Jahromi, Matt Nagle, Gregg E. Trahey, Patrick D. Wolf

Body Part 身体部位
Heart
Modality 模态
US
Abstract / 摘要
English

Diastolic heart failure (DHF) is a major source of cardiac related morbidity and mortality in the world today. A major contributor to, or indicator of DHF is a change in cardiac compliance. Currently, there is no accepted clinical method to evaluate the compliance of cardiac tissue in diastolic dysfunction. Shear wave elasticity imaging (SWEI) is a novel ultrasound-based elastography technique tha...

中文

舒张性心力衰竭(DHF)是全球心脏相关发病率和死亡率的主要原因。DHF的一个重要促成因素或指标是心脏顺应性的变化。目前,没有公认的临床方法来评估舒张功能障碍中心脏组织的顺应性。剪切波弹性成像(SWEI)是一种基于超声的新型弹性成像技术...

Author Info / 作者信息
Maryam Vejdani-Jahromi Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Matt Nagle Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Gregg E. Trahey Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Patrick D. Wolf Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Analysis of Laser Speckle Contrast Images Variability Using a Novel Empirical Mode Decomposition: Comparison of Results With Laser Doppler Flowmetry Signals Variability

使用新型经验模态分解分析激光散斑对比图像的变异性:与激光多普勒血流信号变异性的结果比较

Anne Humeau-Heurtier, Pierre Abraham, Guillaume Mahé

Body Part 身体部位
Skin
Modality 模态
None
Abstract / 摘要
English

Laser Doppler flowmetry (LDF) and laser speckle contrast imaging (LSCI) have emerged as noninvasive optical modalities to monitor microvascular blood flow. Many studies proposed to extract physiological information from LDF by analyzing signals variability. By opposition, such analyses for LSCI data have not been conducted yet. We propose to analyze LSCI variability using a novel data-driven metho...

中文

激光多普勒血流仪(LDF)和激光散斑对比成像(LSCI)已成为监测微血管血流的无创光学方式。许多研究提出通过分析信号变异性从LDF中提取生理信息。相比之下,对LSCI数据进行此类分析尚未进行。我们提出使用一种新的数据驱动方法分析LSCI变异性,并将结果与LDF信号变异性进行比较。

Author Info / 作者信息
Anne Humeau-Heurtier Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Pierre Abraham Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Guillaume Mahé Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Analysis of Structural Similarity in Mammograms for Detection of Bilateral Asymmetry

乳腺X线图像结构相似性分析用于检测双侧不对称

Paola Casti, Arianna Mencattini, Marcello Salmeri, Rangaraj M. Rangayyan

Body Part 身体部位
Breast
Modality 模态
Mammography
Abstract / 摘要
English

We hypothesize that quantification of structural similarity or dissimilarity between paired mammographic regions can be effective in detecting asymmetric signs of breast cancer. Bilateral masking procedures are applied for this purpose by using automatically detected anatomical landmarks. Changes in structural information of the extracted regions are investigated using spherical semivariogram desc...

中文

我们假设,量化配对乳腺X线区域之间的结构相似性或差异性可以有效检测乳腺癌的不对称征象。为此,利用自动检测的解剖标志应用双侧掩膜程序。使用球形半变异函数描述研究提取区域结构信息的变化...

Author Info / 作者信息
Paola Casti Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Arianna Mencattini Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Marcello Salmeri Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Rangaraj M. Rangayyan Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Rigorous Geometric Self-Calibrating Bundle Adjustment for a Dual Fluoroscopic Imaging System

双荧光成像系统的严格几何自校准光束法平差

Derek D. Lichti, Gulshan B. Sharma, Gregor Kuntze, Braden Mund, Jillian E. Beveridge, Janet L. Ronsky

Body Part 身体部位
Bone
Modality 模态
X-Ray
Abstract / 摘要
English

High-speed dual fluoroscopy is a noninvasive imaging technology for three-dimensional skeletal kinematics analysis that finds numerous biomechanical applications. Accurate reconstruction of bone translations and rotations from dual-fluoroscopic data requires accurate calibration of the imaging geometry and the many imaging distortions that corrupt the data. Direct linear transformation methods are...

中文

高速双荧光成像是一种用于三维骨骼运动学分析的无创成像技术,具有众多生物力学应用。从双荧光数据中准确重建骨骼的平移和旋转需要对成像几何以及诸多影响数据的成像畸变进行精确校准。直接线性变换方法是...

Author Info / 作者信息
Derek D. Lichti Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Gulshan B. Sharma Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Gregor Kuntze Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Braden Mund Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Jillian E. Beveridge Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Janet L. Ronsky Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Fast Parallel MR Image Reconstruction via B1-Based, Adaptive Restart, Iterative Soft Thresholding Algorithms (BARISTA)

基于B1的自适应重启迭代软阈值算法的快速并行MR图像重建(BARISTA)

Matthew J. Muckley, Douglas C. Noll, Jeffrey A. Fessler

Body Part 身体部位
Brain
Modality 模态
MRI
Abstract / 摘要
English

Sparsity-promoting regularization is useful for combining compressed sensing assumptions with parallel MRI for reducing scan time while preserving image quality. Variable splitting algorithms are the current state-of-the-art algorithms for SENSE-type MR image reconstruction with sparsity-promoting regularization. These methods are very general and have been observed to work with almost any regular...

中文

促进稀疏性的正则化对于将压缩感知假设与并行MRI相结合以减少扫描时间同时保持图像质量非常有用。变量分裂算法是目前用于具有稀疏性正则化的SENSE型MR图像重建的最先进算法。这些方法非常通用,并且已被观察到几乎适用于任何正则化...

Author Info / 作者信息
Matthew J. Muckley Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Douglas C. Noll Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Jeffrey A. Fessler Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Frequency-Dependent Conductivity Contrast for Tissue Characterization Using a Dual-Frequency Range Conductivity Mapping Magnetic Resonance Method

使用双频范围电导率映射磁共振方法进行组织表征的频率依赖性电导率对比

Dong-Hyun Kim, Munish Chauhan, Min-Oh Kim, Woo Chul Jeong, Hyung Joong Kim, Igor Serša, Oh In Kwon, Eung Je Woo

Body Part 身体部位
Brain
Modality 模态
MRI
Abstract / 摘要
English

Electrical conductivities of biological tissues show frequency-dependent behaviors, and these values at different frequencies may provide clinically useful diagnostic information. MR-based tissue property mapping techniques such as magnetic resonance electrical impedance tomography (MREIT) and magnetic resonance electrical property tomography (MREPT) are widely used and provide unique conductivity...

中文

生物组织的电导率表现出频率依赖行为,不同频率下的电导率值可能提供临床有用的诊断信息。基于磁共振的组织特性映射技术,如磁共振电阻抗断层成像(MREIT)和磁共振电特性断层成像(MREPT),被广泛使用并提供独特的电导率信息。

Author Info / 作者信息
Dong-Hyun Kim Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Munish Chauhan Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Min-Oh Kim Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Woo Chul Jeong Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Hyung Joong Kim Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Igor Serša Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Oh In Kwon Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Eung Je Woo Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

The Evaluation of Data Completeness and Image Quality in Multiplexing Multi-Pinhole SPECT

复用多针孔SPECT中数据完整性和图像质量的评估

Karen Van Audenhaege, Christian Vanhove, Stefaan Vandenberghe, Roel Van Holen

Body Part 身体部位
Brain
Modality 模态
SPECT
Abstract / 摘要
English

Multi-pinhole collimators are often used in pre-clinical SPECT systems because they have a better resolution-sensitivity tradeoff than parallel hole collimators when imaging small objects. Most multi-pinhole collimators are designed to allow no or only a limited amount of overlap between the different pinhole projections because the ambiguity introduced by multiplexing pinholes can result in artif...

中文

多针孔准直器常用于临床前SPECT系统,因为在对小物体成像时,它们比平行孔准直器具有更好的分辨率-灵敏度权衡。大多数多针孔准直器设计为不允许或仅允许不同针孔投影之间存在有限的重叠,因为复用针孔引入的模糊性可能导致伪影...

Author Info / 作者信息
Karen Van Audenhaege Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Christian Vanhove Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Stefaan Vandenberghe Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Roel Van Holen Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

A Gauss-Seidel Iteration Scheme for Reference-Free 3-D Histological Image Reconstruction

一种用于无参考三维组织学图像重建的高斯-赛德尔迭代方案

Simone Gaffling, Volker Daum, Stefan Steidl, Andreas Maier, Harald Köstler, Joachim Hornegger

Body Part 身体部位
Brain
Modality 模态
Microscopy
Abstract / 摘要
English

Three-dimensional (3-D) reconstruction of histological slice sequences offers great benefits in the investigation of different morphologies. It features very high-resolution which is still unmatched by in vivo 3-D imaging modalities, and tissue staining further enhances visibility and contrast. One important step during reconstruction is the reversal of slice deformations introduced during histolo...

中文

组织学切片序列的三维重建在研究不同形态结构方面具有巨大优势。它具有非常高的分辨率,这在体内三维成像模态中仍然无可匹敌,组织染色进一步增强了可见性和对比度。重建过程中的一个重要步骤是逆转组织学过程中引入的切片变形...

Author Info / 作者信息
Simone Gaffling Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Volker Daum Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Stefan Steidl Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Andreas Maier Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Harald Köstler Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Joachim Hornegger Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构

Ming Li, Yadong Liu, Fanglin Chen, Dewen Hu

Body Part 身体部位
Brain
Modality 模态
None
Abstract / 摘要
English

When analyzing brain imaging data, blind source separation (BSS) techniques critically depend on the level of dimensional reduction. If the reduction level is too slight, the BSS model would be overfitted and become unavailable. Thus, the reduction level must be set relatively heavy. This approach risks discarding useful information and crucially limits the performance of BSS techniques. In this s...

中文

在分析脑成像数据时,盲源分离技术关键依赖于降维程度。如果降维程度过小,BSS模型会过拟合而变得不可用。因此,降维程度必须设置得相对较重。这种方法有丢失有用信息的风险,并严重限制了BSS技术的性能。在这项研究中...

Author Info / 作者信息
Ming Li Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Yadong Liu Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Fanglin Chen Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Dewen Hu Affiliation not provided by IEEE Xplore 机构中文翻译待生成或 IEEE 未提供机构
Previous Page 1 of 2 Next